  • Search
  • Home
  • Rosemount
  • Measurement Instrumentation
  • Micro Motion CNG Coriolis Flow Meter Consisting of CNG050S Sensor and 2700 Transmitter
  • Micro Motion CNG Coriolis Flow Meter Consisting of CNG050S Sensor and 2700 Transmitter
Micro Motion CNG Coriolis Flow Meter Consisting of CNG050S Sensor and 2700 Transmitter

Micro Motion CNG Coriolis Flow Meter Consisting of CNG050S Sensor and 2700 Transmitter

(You save )
Brand
Rosemount
SKU:
micro-motion-pkg-ft-cng050s-2700
UPC:

Adding to cart… The item has been added

Description

Batch accuracy: ±0.50% of rate Repeatability: ±0.25% of rate Sensor maximum working pressure: 5,000 psig (345 barg) Meter approvals, calibrations, and certifications: • CSA• IECEx• NEPSI• ATEX Turndown: 10:01 Output variables: Mass & volume flowNet product content / flowTemperatureDensityConcentration Local display: Standard user interface with 2-line LCD panelTwo optical switches for local operationGlass or plastic lens options Power: Self-switching AC/DC input, automatically recognizes supply voltage85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum18 to 100 VDC, 6 watts typical, 11 watts maximumComplies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2 Input/output signals: Not intrinsically safeAnalog output option:One active 4–20 mA outputOne active frequencty outputFrequency output can be configured as a discrete outputConfigurable I/O option:One or two active 4-20 mA outputsOne or two active/passive frequency outputsOne or two active/passive discrete outputsOne discrete inputIntrinsically safeAnalog output option:One passive 4-20 mA outputOne passive frequency outputFrequency output can be configured as a discrete outputFoundation™ fieldbus (Obsolete)optionally non-incendiveOne Foundation fieldbus H1 outputPROFIBUS-PA (Obsolete)One PROFIBUS-PA output HART/WirelessHART: Bell 202 signal is superimposed on the primary milliamp outputWirelessHART available via THUM adapterHART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions Mounting options: Field-mountIntegrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensorRemotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor Application types: Continuous process controlCustody transferTwo-phase flow/entrained gasMeter verificationSIS Certified Hazardous approvals: Class I, Div. 1Class I, Div. 2Zone 1Zone 2 HART/WirelessHART: Bell 202 signal is superimposed on the primary milliamp outputWirelessHART available via THUM adapterHART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions Mounting options: Field-mount•Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor•Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor Application types: Continuous process controlCustody transferTwo-phase flow/entrained gasMeter verificationSIS Certified Hazardous approvals: Class I, Div. 1Class I, Div. 2Zone 1Zone 2
  • Related Products
Micro Motion CNG Coriolis Flow Meter Consisting of CNG050S Sensor and 2500 Transmitter

Rosemount 

Micro Motion CNG Coriolis Flow Meter Consisting of CNG050S Sensor and 2500 Transmitter

Batch accuracy: ±0.50% of rate Repeatability: ±0.25% of rate Sensor maximum working pressure: 5,000 psig (345 barg) Meter approvals, calibrations, and certifications: • CSA• IECEx• NEPSI• ATEX...
Micro Motion CNG Coriolis Flow Meter Consisting of CNG050S Sensor and 1700 Transmitter

Rosemount 

Micro Motion CNG Coriolis Flow Meter Consisting of CNG050S Sensor and 1700 Transmitter

Batch accuracy: ±0.50% of rate Repeatability: ±0.25% of rate Sensor maximum working pressure: 5,000 psig (345 barg) Meter approvals, calibrations, and certifications: • CSA• IECEx• NEPSI• ATEX...
Micro Motion CNG Coriolis Flow Meter Consisting of CNG050S Sensor and 1500 Transmitter

Rosemount 

Micro Motion CNG Coriolis Flow Meter Consisting of CNG050S Sensor and 1500 Transmitter

Batch accuracy: ±0.50% of rate Repeatability: ±0.25% of rate Sensor maximum working pressure: 5,000 psig (345 barg) Meter approvals, calibrations, and certifications: • CSA• IECEx• NEPSI• ATEX...
Micro Motion ELITE Coriolis Meter Consisting of CMF400H Sensor and 2700 Transmitter

Rosemount 

Micro Motion ELITE Coriolis Meter Consisting of CMF400H Sensor and 2700 Transmitter

Mass flow accuracy (Liquid): ±0.10% of rate (standard)±0.05% of rate (optional) Mass flow repeatability (Liquid): ±0.05% of rate (standard)±0.025% of rate (optional) Volume flow accuracy (Liquid): ±0...
Micro Motion ELITE Coriolis Meter Consisting of CMFS075M Sensor and 2700 Transmitter

Rosemount 

Micro Motion ELITE Coriolis Meter Consisting of CMFS075M Sensor and 2700 Transmitter

Mass flow accuracy (Liquid): ±0.10% of rate Mass flow repeatability (Liquid): ±0.05% of rate Volume flow accuracy (Liquid): ±0.10% of rate Volume flow repeatability (Liquid): ±0.05% of rate Mass flow...