-
  • Search
  • Home
  • Rosemount
  • Measurement Instrumentation
  • Rosemount™ 214C RTD Temperature Sensor and 148 Temperature Transmitter
  • Rosemount™ 214C RTD Temperature Sensor and 148 Temperature Transmitter
Rosemount™ 214C RTD Temperature Sensor and 148 Temperature Transmitter

Rosemount™ 214C RTD Temperature Sensor and 148 Temperature Transmitter

(You save )
Brand
Rosemount
SKU:
rosemount-pkg-214c-sensor-and-148-transmitter
UPC:

Adding to cart… The item has been added

Description

Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG wire, FEP insulated; color coded per IEC 60751 Time Constant / Response: 10.8 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 60751:2008 Stability: ±0.15 °C (0.059 ) maximum ice-point resistance shift following 1,000 hours at maximum specified temperature when measured per methods defined in IEC 60751:2008 Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500 VDC at room temperature Calibration Options: IEC 751 Class A or B; Single point calibration; Calibration schedule or customer-specified calibration range, both with Callendar-Van Dusen constants Input: Single sensor capability with universal sensor inputs (RTD, T/C, ohms) Output Signal: 4-20 mA Analog Housing: DIN B head mount Certifications/Approvals: Hazardous location, see full specs for complete list of certifications
  • Related Products
Rosemount™ 214C RTD Temperature Sensor and 248 Temperature Transmitter

Rosemount 

Rosemount™ 214C RTD Temperature Sensor and 248 Temperature Transmitter

Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG...
Rosemount™ 214C RTD Temperature Sensor and 3144P Temperature Transmitter

Rosemount 

Rosemount™ 214C RTD Temperature Sensor and 3144P Temperature Transmitter

Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG...
Rosemount™ 214C RTD Temperature Sensor and 644 Temperature Transmitter

Rosemount 

Rosemount™ 214C RTD Temperature Sensor and 644 Temperature Transmitter

Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG...
Rosemount™ 214C RTD Temperature Sensor, 148 Transmitter and 114C Thermowell

Rosemount 

Rosemount™ 214C RTD Temperature Sensor, 148 Transmitter and 114C Thermowell

Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG...
Rosemount™ 214C RTD Temperature Sensor and 848T Temperature Transmitter

Rosemount 

Rosemount™ 214C RTD Temperature Sensor and 848T Temperature Transmitter

Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG...