  • Search
  • Home
  • Rosemount
  • Measurement Instrumentation
  • Rosemount™ 214C Thermocouple Sensor, 248 Rail Mount Transmitter and 114C Thermowell
  • Rosemount™ 214C Thermocouple Sensor, 248 Rail Mount Transmitter and 114C Thermowell
Rosemount™ 214C Thermocouple Sensor, 248 Rail Mount Transmitter and 114C Thermowell

Rosemount™ 214C Thermocouple Sensor, 248 Rail Mount Transmitter and 114C Thermowell

(You save )
Brand
Rosemount
SKU:
rosemount-pkg-214c-thermocouple-248r-transmitter-and-114c
UPC:

Adding to cart… The item has been added

Description

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of certifications Lead Wires: 24 AWG wire, FEP insulated. Color coded per IEC 60584 or ASTM E230. Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of certifications Input: Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms) Output Signal: 4-20 mA /HART® protocol Housing: DIN rail mount Diagnostics: Basic diagnostics including open/short sensor diagnostics Calibration Options: 5-point calibration Certifications/Approvals: Hazardous location, marine type, RoHS Compliant (Directive 2002/95/EC). See full specs for complete list of certifications Thermowell Calculations: Wake frequency calculation (WFC) performed by certified engineers, order R21 for official report Design Modifiers: Root, bore and tip diameters can be customized for any application Certifications/Approvals: Material certification, NACE, CRN (see full specs for complete list of certifications) Product Tests: External pressure test, internal pressure test, dye penetration, X-ray, PMI (see full specs for complete list)
  • Related Products
Rosemount™ 214C Thermocouple Sensor, 248 Transmitter and 114C Thermowell

Rosemount 

Rosemount™ 214C Thermocouple Sensor, 248 Transmitter and 114C Thermowell

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C Thermocouple Sensor, 248 Wireless Transmitter and 114C Thermowell

Rosemount 

Rosemount™ 214C Thermocouple Sensor, 248 Wireless Transmitter and 114C Thermowell

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C Thermocouple Sensor, 644 Transmitter and 114C Thermowell

Rosemount 

Rosemount™ 214C Thermocouple Sensor, 644 Transmitter and 114C Thermowell

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C Thermocouple Sensor, 148 Transmitter and 114C Thermowell

Rosemount 

Rosemount™ 214C Thermocouple Sensor, 148 Transmitter and 114C Thermowell

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C Thermocouple Sensor, 3144P Transmitter and 114C Thermowell

Rosemount 

Rosemount™ 214C Thermocouple Sensor, 3144P Transmitter and 114C Thermowell

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...