Description

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of certifications Lead Wires: 24 AWG wire, FEP insulated. Color coded per IEC 60584 or ASTM E230. Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of certifications Input: Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms) Output Signal: 4-20 mA /HART® protocol Housing: DIN rail mount Diagnostics: Basic diagnostics including open/short sensor diagnostics Calibration Options: 5-point calibration Certifications/Approvals: Hazardous location, marine type, RoHS Compliant (Directive 2002/95/EC). See full specs for complete list of certifications
  • Related Products
Rosemount™ 214C Thermocouple Sensor and 248 Temperature Transmitter

Rosemount 

Rosemount™ 214C Thermocouple Sensor and 248 Temperature Transmitter

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C Thermocouple Sensor and 248 Wireless Temperature Transmitter

Rosemount 

Rosemount™ 214C Thermocouple Sensor and 248 Wireless Temperature Transmitter

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C Thermocouple Sensor, 248 Rail Mount Transmitter and 114C Thermowell

Rosemount 

Rosemount™ 214C Thermocouple Sensor, 248 Rail Mount Transmitter and 114C Thermowell

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C RTD Temperature Sensor and 248 Rail Mount Temperature Transmitter

Rosemount 

Rosemount™ 214C RTD Temperature Sensor and 248 Rail Mount Temperature Transmitter

Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG...
Rosemount™ 214C RTD Temperature Sensor and 248 Temperature Transmitter

Rosemount 

Rosemount™ 214C RTD Temperature Sensor and 248 Temperature Transmitter

Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG...