-
  • Search
  • Home
  • Rosemount
  • Measurement Instrumentation
  • Rosemount™ 214C Thermocouple Sensor and 3144P Transmitter
  • Rosemount™ 214C Thermocouple Sensor and 3144P Transmitter
Rosemount™ 214C Thermocouple Sensor and 3144P Transmitter

Rosemount™ 214C Thermocouple Sensor and 3144P Transmitter

(You save )
Brand
Rosemount
SKU:
rosemount-pkg-214c-thermocouple-and-3144p-transmitter
UPC:

Adding to cart… The item has been added

Description

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of certifications Lead Wires: 24 AWG wire, FEP insulated. Color coded per IEC 60584 or ASTM E230. Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of certifications Input: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms) Output Signal: 4-20 mA /HART™ protocol, FOUNDATION™ Fieldbus protocol Housing: Dual-compartment field mount Display/Interface: Large LCD display with percent range graph and buttons/switches Diagnostics: Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max tracking Calibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants), custom trim Certifications/Approvals: SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications
  • Related Products
Rosemount™ 214C Thermocouple Sensor, 3144P Transmitter and 114C Thermowell

Rosemount 

Rosemount™ 214C Thermocouple Sensor, 3144P Transmitter and 114C Thermowell

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C Thermocouple Sensor and 648 Transmitter

Rosemount 

Rosemount™ 214C Thermocouple Sensor and 648 Transmitter

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C Thermocouple Sensor and 148 Transmitter

Rosemount 

Rosemount™ 214C Thermocouple Sensor and 148 Transmitter

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C Thermocouple Sensor and 644 Transmitter

Rosemount 

Rosemount™ 214C Thermocouple Sensor and 644 Transmitter

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 214C Thermocouple Sensor and 848T Transmitter

Rosemount 

Rosemount™ 214C Thermocouple Sensor and 848T Transmitter

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...