-
  • Search
  • Home
  • Rosemount
  • Measurement Instrumentation
  • Rosemount™ 3144P Temperature Transmitter
  • Rosemount™ 3144P Temperature Transmitter
Rosemount™ 3144P Temperature Transmitter

Rosemount™ 3144P Temperature Transmitter

(You save )
Brand
Rosemount
SKU:
rosemount-sku-3144p-temperature-transmitter
UPC:

Adding to cart… The item has been added

Description

The Rosemount 3144P Temperature Transmitter provides industry-leading accuracy, stability and reliability for your temperature measurements. It features a dual-compartment housing to ensure reliability and advanced diagnostics to keep your measurement point up and running. When combined with Rosemount X-well™Technology and the Rosemount 0085 Pipe Clamp sensor, this transmitter can provide accurate measurement of process temperature, eliminating the need for a thermowell or process penetration. Input: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms) Output Signal: 4-20 mA /HART™ protocol, FOUNDATION™ Fieldbus protocol Housing: Dual-compartment field mount Display/Interface: Large LCD display with percent range graph and buttons/switches Diagnostics: Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max tracking Calibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants), custom trim Certifications/Approvals: SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications
  • Related Products
Rosemount™ 214C RTD Temperature Sensor and 3144P Temperature Transmitter

Rosemount 

Rosemount™ 214C RTD Temperature Sensor and 3144P Temperature Transmitter

Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG...
Rosemount™ 0085 Pipe Clamp Temperature Sensor and 3144P Temperature Transmitter

Rosemount 

Rosemount™ 0085 Pipe Clamp Temperature Sensor and 3144P Temperature Transmitter

Pipe Clamp Materials: ASTM 304 SST (1.4301), Duplex F51 (1.4462), Carbon steel (1.0037) Lead Wires: PTFE insulated, silver-coated copper wire Insulation Resistance: 1,000 MΩ minimum insulation...
Rosemount™ 214C RTD Temperature Sensor, 3144P Transmitter and 114C Thermowell

Rosemount 

Rosemount™ 214C RTD Temperature Sensor, 3144P Transmitter and 114C Thermowell

Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG...
Rosemount™ 214C Thermocouple Sensor and 3144P Transmitter

Rosemount 

Rosemount™ 214C Thermocouple Sensor and 3144P Transmitter

Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of...
Rosemount™ 148 Temperature Transmitter

Rosemount 

Rosemount™ 148 Temperature Transmitter

The Rosemount 148 Temperature Transmitter is a standard device that can be used with multiple sensor type inputs, providing a cost-effective installation and improved measurement accuracy when...