-
  • Search
  • Home
  • Rosemount
  • Measurement Instrumentation
  • Rosemount™ 975UR Ultraviolet Infrared Flame Detector
  • Rosemount™ 975UR Ultraviolet Infrared Flame Detector
Rosemount™ 975UR Ultraviolet Infrared Flame Detector

Rosemount™ 975UR Ultraviolet Infrared Flame Detector

(You save )
Brand
Rosemount
SKU:
rosemount-sku-975ur-ultraviolet-infrared-flame-detector
UPC:

Adding to cart… The item has been added

Description

The Rosemount 975UR UV/IR Flame Detector senses radiant energy in the short wave section of both the ultraviolet and infrared portions of the electromagnetic spectrum and can detect hydrocarbon-based fuel and gas fires. The signals from both sensors are analyzed for frequency, intensity and duration. Simultaneous detection of radiant energy in both the UV and IR sensors triggers an alarm signal. The UV sensor incorporates a special logic circuit that helps prevent false alarms caused by solar radiation. Communication Protocol: Optional HART™ communications on the 0-20 mA analog current (FSK) - used for maintenance, configuration changes and asset management, available in mA source output wiring options. RS-485 Modbus compatible communication link that can be used in computer controlled installations Ambient Temperature: Operating: -76 °F to +185 °F (-60 °C to +85 °C)Storage: -76 °F to +185 °F (-60 °C to +85 °C) Enclosure Rating: Stainless Steel 316L with electro polish finishHeavy duty copper free aluminum (less than 1%), polyurethane painted Mounting: Stainless Steel 316L with electro polish finish Dimensions: Detector 4"x 4.6"x 6.18"(101.6 x 117 x 157 mm) Weight: Detector (stainless steel 316L) 6.3 lb (2.9 kg)Detector (aluminum) 2.8 lb (1.3 kg)Tilt mount 2.5 lb (1.1 kg) Certifications/Approvals: ATEX and IECEx:Ex II 2 G DEx db eb op is IIC T4 GbEx tb op is IIIC T110 °C Db(Ta -50°C to +85°C) IP66/68FM/FMCClass I, Division 1, Groups B, C, and D, T4AClass II, III, Division 1, Groups E, F, and G, T4AClass I, Division 2, Groups A, B, C, and D, T4Ta = -50°C to +85°CType 6P, IP66/68 2 m for 45 minutesCSA/US:Class I, Division 1, Groups B, C, and D, T4Class II, III, Division 1, Groups E, F, and G, T4Class I, Division 2, Groups A, B, C, and D, T4Ta = -50 °C to +85 °CType 6P; IP 66/68 2 m for 45 minutesTR CU (EAC):1 Ex db eb op is IIC T4 Gb XEx tb op is IIIC T110°C Db X(–55°C Ta +85°C)Performance:EN 54-10 (VdS)FM 3260Reliability:Designed to meet IEC 61508 - SIL 3 (TÜV)Marine:MED "Wheelmark" (DNV)
  • Related Products
Rosemount™ 975UF Ultra Fast Ultraviolet Infrared Flame Detector

Rosemount 

Rosemount™ 975UF Ultra Fast Ultraviolet Infrared Flame Detector

The Rosemount 975UF Ultra Fast Ultraviolet Infrared Flame Detector can detect hydrocarbon-based fuel and gas fires, hydroxyl and hydrogen fires, as well as metal and inorganic fires. This UV/IR flame...
Rosemount™ 975MR Multi-Spectrum Infrared Flame Detector

Rosemount 

Rosemount™ 975MR Multi-Spectrum Infrared Flame Detector

The Rosemount 975MR Multi-Spectrum Infrared Flame Detector accurately analyzes the multi-spectral signals of hydrocarbon gas or liquid fires by utilizing four separate IR sensors. The 975MR detects...
Rosemount™ 975HR Multi-Spectrum Infrared Hydrogen Flame Detector

Rosemount 

Rosemount™ 975HR Multi-Spectrum Infrared Hydrogen Flame Detector

The Rosemount 975HR Multi-Spectrum Infrared Hydrogen Flame Detector is specifically designed for the detection of hydrocarbon and hydrogen flames. It detects hydrocarbon-based fuel and gas fires at...
Rosemount™ Flame Ionisation Detector (FID) (Obsolete)

Rosemount 

Rosemount™ Flame Ionisation Detector (FID) (Obsolete)

This product is now obsolete. Relevant documents and drawings are listed below.Contact your local Emerson representative for your measurement needs.
Rosemount™ Flame Simulator

Rosemount 

Rosemount™ Flame Simulator

The Rosemount Flame Simulator is available in three models to complement the self-testing capabilities of all Rosemount 975 Flame Detectors. The flame simulator emits UV and/or IR radiation in a...