  • Search
  • Home
  • Rosemount
  • Measurement Instrumentation
  • Rosemount™ Flame Simulator
  • Rosemount™ Flame Simulator
Rosemount™ Flame Simulator

Rosemount™ Flame Simulator

(You save )
Brand
Rosemount
SKU:
rosemount-sku-flame-simulator
UPC:

Adding to cart… The item has been added

Description

The Rosemount Flame Simulator is available in three models to complement the self-testing capabilities of all Rosemount 975 Flame Detectors. The flame simulator emits UV and/or IR radiation in a unique pattern recognizable as fire by a Rosemount Flame Detector. This allows the flame detector to be tested under “real” fire conditions without the associated risks of an actual open flame. By simulating a fire that triggers the flame detector outputs, the flame simulator verifies the correct operation of the flame detector, performs an essential end-to-end loop test and verifies window lens cleanliness. The simulator allows remote testing of flame detectors, often located in difficult to access and/or classified hazardous areas (Zones 1 & 2). Temperature Range: -4 °F (-20 °C) to 122 °F (50 °C) Dimensions: 9 in (230 mm) x 7.3 in (185 mm) x 5.35 in (136 mm) Weight: 5.5 lb (2.5 kg) Certifications/Approvals: ATEX and IECEx:Ex II 2 G DEx db ib IIB + H2 T4 GbEx ib tb IIIC T135 °C Db-4 °F (-20 °C) to 122 °F (50 °C)This product is suitable for use in hazardous zones 1 and 2 with IIB + H2 gas group vapor present.UK CAThe Rosemount FS-UVIR-975 is approved per CSAE 21UKEX1171X:Ex II 2 G D Ex db ib op is IIB + H2 T4 GbEx ib op is tb IIIC T135 °C Db-4 °F (-20 °C) to 122 °F (50 °C)This product is suitable for use in hazardous zones 1 and 2 with IIB + H2 gas group vapor present.TR CU:The Rosemount FS-UVIR-975 Flame Simulator is in compliance with the standard TR CU 010/2011 per: 1EX db ib op is IIB + H2 T5 Gb X-20 °C ≤ Ta ≤ +50 °CFor more details, see TR CU certificate No. TR CU C-US.M ю 62.B.05535.InMetro:This device is in compliance with the standards ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1, ABNT NBR IEC 60079-11, ABNT NBR IEC 60079-28, ABNT NBR IEC 60079-31, and INMETRO decree No. 179 as of May 18th, 2010. Further details may be found on Certificate of Compliance No. UL-BR 17.0852XX.
  • Related Products
Rosemount™ 975 Flame Simulator Spare Battery Kit

Rosemount 

Rosemount™ 975 Flame Simulator Spare Battery Kit

Part Number: 00975-9000-0012Compatible with:Rosemount 975MR Multi-Spectrum Infrared Flame DetectorRosemount 975HR Infrared Hydrogen Flame DetectorRosemount 975UF Ultra Fast Ultraviolet Infrared Flame...
Rosemount™ 975UR Ultraviolet Infrared Flame Detector

Rosemount 

Rosemount™ 975UR Ultraviolet Infrared Flame Detector

The Rosemount 975UR UV/IR Flame Detector senses radiant energy in the short wave section of both the ultraviolet and infrared portions of the electromagnetic spectrum and can detect hydrocarbon-based...
Rosemount™ Flame Ionisation Detector (FID) (Obsolete)

Rosemount 

Rosemount™ Flame Ionisation Detector (FID) (Obsolete)

This product is now obsolete. Relevant documents and drawings are listed below.Contact your local Emerson representative for your measurement needs.
Rosemount™ Flame Arrestor Diffuser Hub, Ceramic

Rosemount 

Rosemount™ Flame Arrestor Diffuser Hub, Ceramic

Part Number: 1U05677G01 Compatibility: Rosemount Oxymitter 4000 In Situ Oxygen Analyzer with Probe and Xi Advanced Electronics for Safe AreasRosemount Oxymitter 4000 Replacement Probe for Hazardous...
Rosemount™ CENELEC Flame Arrestor with Snubber Diffuser

Rosemount 

Rosemount™ CENELEC Flame Arrestor with Snubber Diffuser

Part Number: 1U05677G04 Compatibility: Rosemount Oxymitter 4000 In Situ Oxygen Analyzer with Probe and Xi Advanced Electronics for Safe AreasRosemount Oxymitter 4000 Replacement Probe for Hazardous...